The reconstruction of ion temperature profiles from energy-resolved neutral flux measurements in the energy range from 20 eV to 20 keV reveals an uncertainty in positioning the steep gradient region at the plasma edge, even if the measured energy range of the neutral fluxes includes ion temperature values of the gradient region. This empirical observation is studied analytically with a simple model for the neutral particles. Using the line integral of the electron density one finds that translations of the whole ion temperature spectrum with respect to this coordinate cannot be resolved below a certain value. It turns out that the lowest energy for which fluxes can be measured as well as the accuracy of the flux measurements determine the amount of uncertainty, which is in our case . To reduce this uncertainty, the total neutral flux which is determined mainly by neutrals with energies of a few eV or less, has been fitted simultaneously with the absolutely calibrated energy-resolved flux spectra. The total neutral flux can be measured with an ion gauge and is closely related to the emissivity. The fit of the total neutral flux or the signal requires simulation of the ionization zone in the scrape-off layer, i.e. measured electron temperatures must be combined with an accurate model for the dissociation and ionization of molecules and atoms.
20 eVから20 keVのエネルギー範囲におけるエネルギー分解中性粒子フラックス測定からのイオン温度プロファイルの再構成は、測定された中性粒子フラックスのエネルギー範囲が勾配領域のイオン温度値を含む場合でも、プラズマ端部における急峻勾配領域の位置決めにおける不確かさを明らかにする。この経験的観察は、単純なモデルを用いた中性粒子の解析的研究によって検討される。電子密度の線積分を用いると、この座標に対するイオン温度スペクトル全体の並進は、ある値以下では分解できないことが分かる。フラックスを測定できる最低エネルギーとフラックス測定の精度が、不確かさの大きさを決定することが判明し、これは我々の場合においては[特定の値]である。この不確かさを低減するため、主に数eV以下のエネルギーを持つ中性粒子によって決定される全中性粒子フラックスが、絶対較正されたエネルギー分解フラックススペクトルと同時にフィッティングされた。全中性粒子フラックスはイオンゲージで測定でき、[特定の]放射率と密接に関連している。全中性粒子フラックスまたは[特定の]信号のフィッティングには、スクレイプオフ層における電離のシミュレーションが必要であり、すなわち、測定された電子温度は、分子および原子の解離と電離の正確なモデルと組み合わせなければならない。