AbstractThe measurement of the total microwave power in ECRH applications is commonly accomplished by directional couplers or mirrors with gratings which deflect a small portion of the power in conjunction with diode detectors. The nearly quadratic characteristic of a solid state diode allows for the direct measurement of the radiated power. It has an instantaneous response, but the quasi-quadratic behavior is limited to a certain range of the characteristic and the power is measured only at the (quite localized) position of the coupler. The first constraint limits the dynamic range of the measurement and the second introduces errors due to the transverse shift of the beam during long pulses. These drawbacks can be avoided by measuring the window loss power calorimetrically. A calorimeter is described which evaluates the flow rate and temperature difference of the cooling circuit of a vacuum window or mirror.
ECRH応用におけるマイクロ波全電力の測定は、通常、方向性結合器またはグレーティングを有するミラーによって行われ、これらは電力の一部を偏向させ、ダイオード検出器と組み合わせて使用される。固体ダイオードのほぼ2乗特性により、放射電力の直接測定が可能となる。これは瞬時応答を示すが、その準2乗特性は特定の特性範囲に限定され、また電力は結合器の(極めて局所的な)位置でのみ測定される。第1の制約は測定のダイナミックレンジを制限し、第2の制約は長パルス中のビームの横方向シフトによる誤差を生じさせる。これらの欠点は、窓損失電力を熱量計的に測定することで回避できる。本論文では、真空窓またはミラーの冷却回路における流量と温度差を評価する熱量計について述べる。