AbstractIn the next large tokamak facility such as the International Thermonuclear Experimental Reactor (ITER), the ion cyclotron range of frequency (ICRF) heating is one of the major techniques to heat the plasma. Due to the existence of the resonance peak for the D-T fusion reaction around 100 keV, the neutron yield of ICRF heated D-T plasma might decrease due to the growth of a high energy tritium ion tail when the temperature of the tail component exceeds ∼ 150 keV. On the contrary, the peak width of the D-T neutron spectrum increases monotonically as the tail temperature increases. 'Therefore, the neutron spectrum measurement could be a useful tool for monitoring the effect of ICRF heating on D-T fusion plasma. In this paper, the necessary performance of a neutron spectrometer will be discussed.
次世代の大型トカマク装置、例えば国際熱核融合実験炉(ITER)において、イオンサイクロトロン周波数帯(ICRF)加熱はプラズマを加熱する主要な手法の一つである。D-T核融合反応の共鳴ピークが約100 keV付近に存在するため、高エネルギーのトリチウムイオンテイルが形成されると、ICRF加熱を受けたD-Tプラズマにおける核融合収量は減少する可能性がある。逆に、テイル温度が約150 keVを超えると、D-T核融合反応断面積の増大により核融合収量は増加する。したがって、ICRF加熱を受けたD-Tプラズマから放出される中性子スペクトルを測定することは、高エネルギーイオンのテイル温度と閉じ込め特性を理解する上で極めて重要である。本論文では、D-T核融合プラズマにおけるICRF加熱の効果を監視するために必要な中性子スペクトロメータの性能要件について議論する。