The technology readiness level scale is revised with clear definitions for magnetohydrodynamic stability control technologies for magnetic confinement fusion. The definitions are in the form of a sentence with three dimensions, which are the system complexity, the test environment, and the cost. A clear and simple definition is sought after to make an assessment based on the evidence which is agreeable to the fusion energy development community. A sample technology readiness assessment (TRA) for the electron cyclotron current drive-based control of neoclassical tearing mode for ST Advanced Reactor, using the proposed scale, reveals that the risk of a TRA being misinterpreted is high, which can only be avoided with an understanding of the procedure described in this paper.