The ITER vertical stabilization coil system is designed to provide fast plasma stabilization in all scenarios with elongated plasma cross-section. It consists of two water-cooled coils located in upper and lower portions of the vacuum vessel (VV), with feedthroughs responsible for the transfer of electricity and cooling water across the vacuum boundary of VV. Depending on location, the feedthroughs can be divided into upper port feedthroughs (UPR feedthroughs) and lower port feedthroughs (LWR feedthroughs), each family sharing the same design. Both designs are subject to demanding operation scheme, a severe working environment and the presence of interfacing components, which impose important thermal, electromagnetic and seismic loads on the components. In particular, the LWR feedthrough, object of present paper, is more impacted by seismic loads due to the more flexible structure compared to the UPR feedthrough. During the worst seismic event, it is subjected to a vertical acceleration of 28.8 m s−2, acting on an effective mass of 249.9 kg at its first order modal mode. Furthermore, the current circulating in the conductor of the LWR feedthrough, impose significant linear forces, up to 27.7 kN m−1 during normal operation and 30.3 kN m−1 during categories I & II abnormal plasma events, respectively. Finally, the effect of differential thermal expansions of interfacing structures imposes a relative displacement between the supports up to 32.9 mm in X (radial) direction and up to 14.67 mm in Z (vertical) direction, during baking. Being part of the vacuum boundary, the feedthrough must assure confinement function under all normal and accidental loading conditions, with proper structural integrity assessment by applying analysis approach and design criteria foreseen by the applicable nuclear codes. The paper details the load types and categories, the analysis methodologies, the structural design criteria, and the assessment results in views of static stress and fatigue for the LWR feedthrough. This study could be a comprehensive reference for the structural integrity assessment of other similar components in fusion devices.
ITER垂直安定化コイルシステムは、細長いプラズマ断面を有する全てのシナリオにおいて高速プラズマ安定化を提供するように設計されている。本システムは、真空容器(VV)の上部および下部に配置された2つの水冷コイルで構成され、フィードスルーは真空容器の境界を横切る電気と冷却水の伝送を担う。位置に応じて、フィードスルーは上部ポートフィードスルー(UPRフィードスルー)と下部ポートフィードスルー(LWRフィードスルー)に分類でき、各ファミリーは同一の設計を共有する。両設計は、過酷な運転スキーム、厳しい動作環境、およびインターフェース部品の存在にさらされ、これらはコンポーネントに重要な熱的、地震的、および電磁的負荷を課す。特に、本論文の対象であるLWRフィードスルーは、UPRフィードスルーと比較してより柔軟な構造のため、地震負荷の影響をより強く受ける。最悪の地震事象時には、1次モーダルモードにおいて249.9 kgの有効質量に作用する28.8 m s⁻²の垂直加速度を受ける。さらに、LWRフィードスルーの導体を循環する電流は、通常運転時には最大27.7 kN m⁻¹、カテゴリーIおよびIIの異常プラズマ事象時には30.3 kN m⁻¹の有意な線力を課す。最後に、インターフェース構造の差動熱膨張の影響により、ベーキング中に支持部間で半径方向(X方向)に最大32.9 mm、垂直方向(Z方向)に最大14.67 mmの相対変位が生じる。フィードスルーは真空境界の一部であるため、適用可能な原子力コードによって想定される解析アプローチと設計基準を適用した適切な構造健全性評価により、全ての通常および事故時荷重条件下で閉じ込め機能を保証しなければならない。本論文は、LWRフィードスルーの荷重タイプとカテゴリー、解析方法論、構造設計基準、ならびに静的応力および疲労に関する評価結果を詳述する。本研究は、核融合装置における他の類似コンポーネントの構造健全性評価のための包括的な参考資料となり得る。