The magnetic field configuration of the Uragan-3M l=3 torsatron, which has a p=4 multipole vertical magnetic field compensation system, was studied using two methods to map the contours of the magnetic flux surfaces. The first method, the so-called triode method with a constant voltage electron source, measures the current emitted by an open thermoelectron emitter and the portion drawn by a highly transparent grid located in a poloidal cross-section of the torus. The second method involves the use of a conducting luminescent rod which scans the torus cross-section and lights up when struck by electrons emitted by an electron gun. The information on the magnetic surface structure obtained by these two techniques is compared. The characteristics of the two methods are discussed, giving special attention to the triode method because it allows an objective criterion for the quality of the magnetic surface structure to be introduced. It is shown how advantageous both methods are for rapid adjustment and optimization of the magnetic configurations in a stellarator when perturbations are present and what improvements could be achieved on Uragan-3M. Also discussed are experiments on generating electron clouds in Uragan-3M during the ramp-up phase of the magnetic field pulse
Uragan-3M l=3トルサトロンの磁場配位は、p=4多重極垂直磁場補償システムを有し、磁気面の輪郭をマッピングするための2つの方法を用いて研究された。第一の方法は、いわゆる三極管法であり、一定電圧の電子源を用いて、開放型熱電子エミッターから放出される電流と、トーラスのポロイダル断面に配置された高透過性グリッドによって引き出される電流を測定する。第二の方法は、導電性発光ロッドを用いるものであり、このロッドはトーラス断面を走査し、電子銃から放出された電子が衝突すると発光する。これら2つの手法によって得られた磁気面構造の情報が比較された。両手法の特性が議論され、特に三極管法に注目が払われた。なぜなら、この方法は磁気面構造の品質に関する客観的な基準を導入することを可能にするからである。摂動が存在する場合のステラレーターにおける磁気配位の迅速な調整と最適化に対する両手法の有用性が示され、Uragan-3Mにおいて達成可能な改善点が明らかにされた。さらに、磁場パルスの立ち上がり段階におけるUragan-3Mでの電子雲生成に関する実験についても議論された。