This paper presents the results of a study of the increase in impurity line radiation in the 15-360 Å region during ICRF heating of PLT plasmas, with emphasis on metallic impurity (Ti and Fe) behaviour. Central titanium and iron densities are given for a variety of ICRF heating experiments; total central metallic impurity concentrations of up to about 0.3% of ne(0) are observed at the 2.0 MW RF power level. This study shows that the power radiated by these elements is a small (about 10%) fraction of the total input power to the plasma for the present heating efficiency at 2.0 MW RF power. The impurity line brightnesses scale approximately linearly with RF power up to 2.8 MW. The antenna Faraday shields are shown to be the primary source of metallic impurities during both ICRF heating and Ohmic heating only. The impurity content of discharges heated using a single half-turn antenna and a pair of centre-fed antennas (having the same total surface area but half the poloidal extent of the half-turn antenna) is the same at a relatively low RF power of 350 kW, indicating that the impurity influx does not depend on the poloidal length of the antennas (or that the plasma interacts only with a localized area on the Faraday shields).
本論文は、PLTプラズマのICRF加熱中における15〜380 Å領域の不純物線放射の増加に関する研究結果を提示し、金属不純物(TiおよびFe)の挙動に焦点を当てている。様々なICRF加熱実験における中心部のチタン密度と鉄密度を示し、2.0 MWのRF電力レベルにおいて、中心部の全金属不純物濃度はne(0)の約0.3%まで観測された。本研究は、これらの元素によって放射される電力は、現在の加熱効率において2.0 MWのRF電力でのプラズマへの全入力電力のわずか約10%であることを示している。不純物線の輝度は、RF電力が2.8 MWまでほぼ線形にスケーリングする。アンテナのファラデーシールドが、ICRF加熱時およびオーミック加熱時のみの両方において、金属不純物の主要な供給源であることが示されている。単一のハーフターンアンテナと一対のセンター給電アンテナ(全表面積は同一であるが、ポロイダル方向の広がりがハーフターンアンテナの半分)を用いた放電における不純物含有量は、比較的低い350 kWのRF電力において同一であり、不純物の流入はアンテナのポロイダル長に依存しないこと(または、プラズマがファラデーシールド上の局所的な領域とのみ相互作用すること)を示している。