The Uragan-3M device is equipped with two antennas which are fed by RF power with the frequency below ion cyclotron. The frame antenna was used for pre-ionization and the three-half turn antenna makes plasma heating. In this experimental series, the radial profiles of C III, O V and C V optical line intensity and the second cyclotron harmonic emission are measured using a pulse-by-pulse technique. The results of these measurements and Biot–Savart calculations of the Uragan-3M magnetic configuration could be explained by the existence of a small central area with relatively high electron temperature and good plasma confinement surrounded by a zone where the electron temperature and confinement are worse. The relatively low average electron temperature and high RF power needed to sustain plasma are the consequences.
Uragan-3M装置には、イオンサイクロトロン周波数以下の周波数のRF電力で給電される2つのアンテナが装備されている。フレームアンテナは予備電離に使用され、3半ターンアンテナはプラズマ加熱を行う。今回の実験シリーズでは、パルス毎測定法を用いて、C III、O V、C Vの光学輝線強度の動径分布と、第2サイクロトロン高調波放射を測定した。これらの測定結果と、Uragan-3M磁気配位のビオ・サバール計算により、比較的高い電子温度と良好な閉じ込めを有する小さな中心領域が存在し、その周囲を電子温度と閉じ込めが劣る領域が取り囲んでいることが示された。平均電子温度が比較的低く、プラズマ維持に高いRF電力が必要であることは、その結果である。