AbstractWe present the results of fast time scale plasma control simulations for the proposed Korea Superconducting Tokamak Advanced Research (KSTAR) tokamak. Here, the fast plasma control includes stabilization of the vertical instability and rapid radial position control. As a simulation tool, we use the tokamak simulation code (TSC). We evaluate the power supply requirements for both the vertical and radial position control with a similar approach to that which was employed in the analysis of the tokamak physics experiments (TPX). In particular, we investigate the efficacy of control coil locations to minimize the power supply requirements. From this study, it is shown that two separate sets of control coils, one responsible for vertical control and the other responsible for radial control, are required to provide robust control of both vertical and radial position for all the anticipated plasmas in KSTAR experiments.
本論文では、提案されているKSTAR(韓国超伝導トカマク先進研究)装置における高速時間スケールのプラズマ制御シミュレーションの結果を提示する。ここで、高速プラズマ制御には、垂直不安定性の安定化と高速な径方向位置制御が含まれる。シミュレーションツールとして、トカマクシミュレーションコード(TSC)を用いる。我々は、トカマク物理実験(TPX)の解析で採用された手法と同様のアプローチで、垂直および径方向位置制御の両方に対する電源要件を評価する。特に、電源要件を最小化するための制御コイル位置の有効性を調査する。この研究から、KSTAR実験において想定される全てのプラズマに対して、垂直方向と径方向の両方の位置制御を堅牢に実現するには、垂直制御用と径方向制御用の2つの独立した制御コイルセットが必要であることが示された。