The ITER Threshold Database, which at present comprises data from nine divertor tokamaks, is described. The main results are presented and discussed. The properties and dependences of the power threshold in individual devices are reviewed. In particular, the analysis shows a rather general linear dependence on magnetic field, but a non-monotonic density dependence that varies from device to device. Investigation of the combined database suggests that the threshold dependence Pthres approximately=0.3neBT2.5 shows reasonable agreement with the data. This expression yields Pthres approximately=150 MW at a density of 0.5*1020 m-3 for ITER. Other expressions with weaker size dependence, and therefore lower threshold power for ITER, are also discussed. Their agreement with the present data is poorer than that of the above expression. In addition, the database is investigated by statistical discriminant analysis. The edge data included at present are described and discussed. Finally, there is a discussion of the implications of the results for ITER
ITER閾値データベースについて述べる。このデータベースは現在、9つのダイバータトカマクからのデータで構成されている。主な結果を示し、考察する。個々の装置におけるパワー閾値の特性と依存性を概説する。特に、解析により、磁場に対しては概ね線形の依存性が示される一方、密度に対しては非単調な依存性が示され、これは装置ごとに異なる。統合データベースの調査により、閾値依存性P閾値≒0.3neBT2.5がデータと良好な一致を示すことが示唆される。この式は、ITERについて、密度0.5×10^20 m^-3においてP閾値≒150 MWを与える。サイズ依存性がより弱く、したがってITERの閾値パワーがより低くなる他の式についても考察する。これらと現行データとの一致度は、上記の式よりも低い。さらに、データベースを統計的判別分析により調査する。現在含まれている周辺データについて記述し、考察する。最後に、これらの結果がITERに与える影響について考察する。