AbstractNeutron spectrum measurements in a cylindrical assembly of 316L stainless steel were carried out for DT neutrons to assess the multigroup neutron cross section libraries and the calculational method for fusion neutronics. Energy spectra of scalar flux in the assembly above 0.8 MeV were measured at the positions of 8 to 88 cm in depth using a small spherical NE213 liquid scintillator with an unfolding code FORIST. The measured spectra were analyzed with the two-dimensional transport code DOT3.5 by using three multigroup cross section libraries originated from the ENDF/B-III, -IV, and JENDL-2 and -3PR1 nuclear data files. The calculated spectra with the 42-group library from ENDF/B-III are not consistent with the measured ones in shape. Calculation with the 125-group library from ENDF/B-IV overestimates the measured spectra in the whole energy region at every position, because of the uncertainty in the non-elastic cross section for Cr and the elastic and non-elastic cross sections for Fe. The best agreement is obtained between the measurement and the calculation using the 125-group library from JENDL-2 and -3PR1.
円筒形316Lステンレス鋼アセンブリ内でのDT中性子に対する中性子スペクトル測定を実施し、多群中性子断面積ライブラリと核融合中性子工学のための計算手法を評価した。深さ8cmから88cmの位置において、小型球形NE213液体シンチレータとアンフォールディングコードFORISTを用いて、0.8MeV以上のスカラー束のエネルギースペクトルを測定した。測定スペクトルは、ENDF/B-III、ENDF/B-IV、JENDL-2およびJENDL-3PR1の核データファイルに基づく3つの多群断面積ライブラリを用いた2次元輸送コードDOT3.5によって解析された。ENDF/B-IIIに基づく42群ライブラリによる計算スペクトルは、その形状において測定結果と一致しなかった。ENDF/B-IVに基づく125群ライブラリによる計算は、Crの非弾性散乱断面積ならびにFeの弾性および非弾性散乱断面積の不確かさにより、全エネルギー領域の全位置において測定スペクトルを過大評価した。JENDL-2およびJENDL-3PR1に基づく125群ライブラリを用いた計算と測定結果の間に最も良い一致が得られた。