AbstractHigh energy neutral Li beam probes have advanced to the point where they are a standard diagnostic tool on W7-AS and ASDEX-Upgrade, both in terms of the Li beam injector and the reconstruction algorithm to arrive at densities ne(z) along the beam from the Li[2p-2s] resonance line profile. With beam energies in the range 30–70 keV and neutral equivalent currents greater than 1 mA, it is possible to derive ne(z) profiles for line densities nez < 4 × 1014 cm−2, with a radial resolution of about 0.5 cm and time response of less than 0.2 ms. By way of example, the diagnostic layout on the W7-AS stellarator is sketched and salient results from experiments discussed. Densities over the range 1012–1014 cm−3 are accessible, permitting full coverage of the core density gradient region on W7-AS. Examples from the ASDEX tokamak that involve the H-mode and pellet injection are presented to exemplify the time response.
高エネルギー中性Liビームプローブは、W7-ASおよびASDEX-Upgradeにおける標準的な診断ツールとなるまでに進歩しており、Liビーム入射器と、Li[2p-2s]共鳴線プロファイルからビームに沿った密度ne(z)を導出する再構成アルゴリズムの両方の点で成熟している。ビームエネルギー30〜70 keV、中性等価電流1 mA超において、線密度nez < 4 × 10^14 cm^−2に対するne(z)プロファイルを、約0.5 cmの動径分解能と0.2 ms未満の時間応答で導出することが可能である。一例として、W7-ASステラレーターにおける診断レイアウトを概説し、実験から得られた顕著な結果について考察する。10^12〜10^14 cm^−3の範囲の密度が測定可能であり、W7-ASにおけるコア密度勾配領域の完全なカバーが可能となる。時間応答を例証するために、Hモードとペレット入射を含むASDEXトカマクからの例を示す。