The work represents a next step in studies of longitudinal energy losses from linear magnetic plasma confinement devices. The paper describes the experimental technique that has been developed and used to measure the absolute values of longitudinal particle and energy density fluxes from an open magnetic mirror trap. Using this technique, it was possible to measure and account for the secondary electron emission coefficient from plasma-facing end plate, and perform a comparison with the existing theory of energy confinement in open traps. It is shown that the average energy transported by an ion-electron pair leaving the trap is close to theoretically predicted minimum value of 6–8 electron temperatures. As confirmed by the measured dependencies, this conclusion is valid in a broad range of parameters and the threshold value of the magnetic expansion ratio does not exceed its theoretically predicted minimum of .
この研究は、線形磁気プラズマ閉じ込め装置からの縦方向エネルギー損失に関する研究の次のステップを表すものである。本論文では、開放型磁気ミラー装置からの縦方向粒子およびエネルギー束密度の絶対値を測定するために開発され、使用されてきた実験手法について述べる。この手法を用いることで、プラズマ対向端板からの二次電子放出係数を測定し、考慮に入れることが可能となり、開放型磁気ミラー装置におけるエネルギー閉じ込めの既存理論との比較を行うことができた。装置から出るイオン・電子対が運ぶ平均エネルギーは、理論的に予測される最小値である6〜8電子温度に近いことが示された。測定された依存性によって確認されたように、この結論は広範囲のパラメータにおいて有効であり、磁気拡大比の閾値は理論的に予測される最小値である.を超えない。