A pulse of methane gas is injected into the DIVA tokamak. The major portion of the injected impurity is shielded by the outer edge plasma, i.e. only 20% of the injected carbon are introduced into the discharge. After radial penetration of the injected carbon has been accomplished, accumulation doubles and a new steady state is sustained over the period of proton confinement. The transient radial diffusion process of the carbon is compared with calculations using an impurity transport code. The behaviour of the carbon impurity in the whole minor radius is well described by assuming perfect re-cycling at the gold-plated shell surface and using neoclassical diffusion superposed by anomalous diffusion of protons. It is shown that spreading caused by anomalous diffusion is important. The calculated result indicates that the carbon ions are lost dominantly in a He-like state.
メタンガスのパルスがDIVAトカマクに注入される。注入された不純物の大部分は外周プラズマによって遮蔽され、すなわち注入された炭素のわずか20%のみが放電中に導入される。注入された炭素の径方向への浸透が達成された後、蓄積は2倍になり、陽子閉じ込めの期間にわたって新しい定常状態が維持される。炭素の過渡的な径方向拡散過程は、不純物輸送コードを用いた計算と比較される。主半径全体にわたる炭素不純物の挙動は、金メッキされたシェルでの完全な再循環を仮定し、陽子の異常拡散に重畳された新古典拡散を用いることでよく記述される。異常拡散によって引き起こされる広がりが重要であることが示される。計算結果は、炭素イオンがHe様状態で支配的に損失されることを示している。