We report on recent advances in modelling and experiments on resistive wall mode feedback control. The first experimental demonstration of feedback suppression of rotating external kink modes near the ideal wall limit in a tokamak is described [1]. This was achieved using an optimized control system employing a low latency digital controller and directly coupled modular feedback coils. The magnitude of plasma dissipation affecting kink mode behaviour has also been experimentally quantified for the first time using measurements of the radial eigenmode structure of the poloidal field fluctuations associated with the rotating kink mode. New capabilities of the VALEN code [2] are also reported. These include the ability to simulate multiple plasma modes and mode rotation in the model of the feedback control loop. Results from VALEN modelling of resistive wall mode feedback control in ITER are also presented, showing a significant improvement in performance with internal coils. Evidence for a lack of mode rigidity in HBT-EP is given, and plans to address this and other issues related to coil coverage and coil modularity are presented.
我々は、抵抗性壁モードのフィードバック制御に関するモデリングと実験の最近の進展について報告する。トカマクにおける理想壁限界付近での回転外部キンクモードのフィードバック抑制の初めての実験的実証が記述されている[1]。これは、低遅延デジタルコントローラと直接結合されたモジュール型フィードバックコイルを採用した最適化された制御システムを用いて達成された。キンクモードの挙動に影響を与えるプラズマ散逸の大きさも、回転キンクモードに伴うポロイダル磁場変動の動径固有モード構造の測定を用いて、初めて実験的に定量化された。VALENコード[2]の新機能も報告される。これには、フィードバック制御ループのモデルにおいて複数のプラズマモードとモード回転をシミュレートする能力が含まれる。ITERにおける抵抗性壁モードフィードバック制御のVALENモデリングの結果も提示され、内部コイルによる性能の大幅な向上が示されている。HBT-EPにおけるモード剛性の欠如の証拠が示され、コイル被覆率とコイルのモジュール性に関連するこの問題およびその他の問題に対処する計画が提示される。