Two visible cameras with the same wide-angle view have been used to study the gross beryllium (Be) erosion in JET. An absolutely calibrated spectroscopy system employed in the past for the same object was used to quantitatively infer the camera photon fluxes and also to validate the results. To extract the effective sputtering yield, a simplified method is applied from the quotient of the measured radiances of the Dα and the Be II line at 527 nm. The obtained results are in reasonably good agreement with those already published. The main benefit of using cameras is that the global view of the plasma–wall interaction surfaces of the whole vessel is monitored, and the different sources and their wetted areas can be identified and quantified. In addition, the measurement of the particle flux distributions can be used for the validation of three-dimensional erosion-transport codes.
2台の同一の広視野カメラを用いて、JETにおけるベリリウム(Be)の総合的な侵食を研究した。過去に同じ目的で使用された絶対較正分光システムを用いて、カメラの光子フラックスを定量的に推定し、その結果を検証した。有効スパッタリング収率を導出するため、Dα線と527 nmのBe II線の測定放射輝度の比から簡略化した手法を適用した。得られた結果は、既に発表されている結果と良好な一致を示した。カメラを使用する主な利点は、プラズマ・壁相互作用面の全体像を監視できることであり、異なる発生源とその濡れ面積を特定・定量化できることである。さらに、粒子フラックス分布の測定は、3次元の侵食・輸送コードの検証に使用できる。