Time-resolved arcs have been observed in the DITE tokamak using three independent techniques, the observation of the current flowing to a probe, the spectral emission from the probe material, and the arc tracks on a rotating disc. The results obtained with the different methods are in good agreement and show that arcing typically occurs in DITE during the first 20 ms of the discharge. This short period of arcing is consistent with measurements of the metal impurity flux at the wall, which show a similar time dependence. Observations of the arc current as a function of radial position show that arcing is negligible 3 cm beyond the radius of the fixed limiter, in good agreement with the observed arc tracks on projecting surfaces of the torus. The erosion of a probe was estimated from the charge flowing in the arcs and is consistent with previous measurements of the metal impurities deposited at the torus wall.
時間分解されたアークは、DITEトカマクにおいて、プローブに流れる電流の観測、プローブ材料からのスペクトル放射、および回転ディスク上のアーク痕という3つの独立した手法を用いて観測された。異なる手法で得られた結果は良好に一致し、アークがDITEにおいて典型的に放電の最初の20 msの間に発生することを示している。この短いアーク発生期間は、壁における金属不純物フラックスの測定結果と一致しており、同様の時間依存性を示す。アーク電流の半径方向位置に対する観測から、アークは固定リミターの半径から3 cmを超えると無視できることが示され、トーラスの突出面上に観測されたアーク痕と良好に一致する。プローブの侵食はアークを流れる電荷から推定され、トーラス壁に堆積した金属不純物の以前の測定結果と一致している。