ICRH has proved to be an efficient method of heating the plasma in toroidal devices. The high voltages needed at the coupling structure are, however, a severe handicap of this method. The possibility is investigated of having the highest voltages between the bars of the Faraday shield (FS), where they are both necessary and easier to maintain. For this purpose a resonant Faraday shield (RFS) antenna where the first and last bars of the FS are connected by an inductive strip is proposed. In front of this strip there is a second strip, fed, as in a conventional antenna, by an RF generator. It is shown that if the toroidal length of the FS is larger than λ/2 the strip connecting the bars of the FS acts as the secondary coil of a tuned transformer, the strip fed by the generator being the primary. It is therefore possible, by varying the frequency and the distance between the two strips, i.e. the coupling coefficient, to match the impedance of the primary to that of the generator.
ICRHは、トロイダル装置におけるプラズマ加熱の効率的な方法であることが実証されている。しかしながら、結合構造に必要な高電圧は、この方法の重大な欠点である。本論文では、ファラデーシールド(FS)のバー間に最高電圧が生じる可能性について調査する。そこでは、高電圧は必要であると同時に維持が容易である。この目的のために、FSの最初と最後のバーが誘導ストリップによって接続された共振ファラデーシールド(RFS)アンテナを提案する。このストリップの前方には、従来のアンテナと同様にRF発振器によって給電される第2のストリップが配置される。FSのトロイダル長がλ/2より大きい場合、FSのバーを接続するストリップは同調変圧器の二次コイルとして機能し、発振器によって給電されるストリップが一次コイルとなることが示される。したがって、周波数と2つのストリップ間の距離、すなわち結合係数を変化させることにより、一次側のインピーダンスを発振器のインピーダンスに整合させることが可能である。