AbstractIt is envisaged that exhaust control in tokamak fusion reactors, e.g. NET, ITER and DEMO, will be achieved using poloidal divertors. The targets for these divertors, which will receive substantial quantities of heat from, and may be eroded by, the exhausted particles, present a significant engineering challenge. Here a systematic approach has been derived to identify viable design options given the limits imposed by the practicalities of cooling and structural integrity. As an example target designs for DEMO-DN (a DEMO version of NET-DN) are presented which are capable of handling a peak heat flux of 13 MW/m2.The exhaust particles and heat arrive at the target along the field lines which intersect it at a shallow angle of attack (≈1°). Hence small perturbations in target or field geometry can lead to large changes in local heat flux, producing hot spots. Perturbations due to field ripple, thermal distortion, target manufacturing errors and discontinuities at junctions in the target assembly have been quantified. For the DEMO-DN example these perturbations produce significant, but seemingly manageable, hot spots.
トカマク核融合炉、例えばNET、ITER、DEMOにおける排気は、ポロイダルダイバータを用いて達成されることが想定されている。これらのダイバータのターゲットは、排気粒子から相当量の熱を受け、またそれによって侵食される可能性があり、重大な工学的課題を提示している。ここでは、冷却および構造的完全性の実用性によって課される制約を考慮した上で、実現可能な設計オプションを特定するための体系的なアプローチが導出されている。例として、DEMO(NETのDEMO版)のターゲット設計が提示されており、これは13 MW/m²のピーク熱流束に対処することが可能である。排気粒子と熱は、約1°の浅い角度でターゲットと交差する磁力線に沿って到達する。したがって、ターゲットまたは磁場形状のわずかな摂動が、局所的な熱流束の大きな変化をもたらし、ホットスポットを生じさせる可能性がある。磁場リップル、熱変形、ターゲットの製造誤差、およびターゲットアセンブリの接合部における不連続性による摂動が定量化されている。DEMOの例では、これらの摂動は顕著ではあるものの、対処可能と思われるホットスポットを生じさせる。