The nine-channel 337 μm interferometer/polarimeter on the TEXTOR tokamak has been used to detect and control the horizontal plasma position in two different ways. (1) The phase shift between two vertical probing beams located at a distance of x/a = ±0.6 from the vessel centre yields the difference of electron line densities along these trajectories and indicates displacements or asymmetries of the density profile. (2) Faraday rotation measurements on a probing beam passing vertically through the vessel centre allow horizontal shifts of the magnetic flux surfaces to be detected. Both the phase shift and Faraday rotation signals have been applied as control quantities to the TEXTOR feedback system, resulting in good positional stability for discharge durations of more than 2.5 seconds.
TEXTORトカマク上の9チャンネル337 μm干渉計/偏光計は、水平プラズマ位置を2つの異なる方法で検出し制御するために使用されてきた。(1) 容器中心から x/a = ±0.6 の距離に位置する2本の垂直プロービングビーム間の位相シフトは、これらの軌道に沿った電子線密度の差を与え、密度分布の変位または非対称性を示す。(2) 容器中心を垂直に通過するプロービングビームに対するファラデー回転測定により、磁束面の水平方向のシフトを検出できる。位相シフトとファラデー回転信号の両方がTEXTORフィードバックシステムの制御量として適用され、2.5秒以上の放電時間にわたって良好な位置安定性が得られた。