An escaping alpha collector probe has been developed for the deuterium-tritium (DT) phase of the Tokamak Fusion Test Reactor (TFTR) to complement the results of the lost alpha scintillator detectors, which have been operating on TFTR since 1988. Measurements of the energy distribution of escaping alphas have been made by measuring the range of alphas implanted into nickel foils located within the alpha collector. Exposed samples have been analysed for four DT plasma discharges at plasma currents of 1.0 and 1.8 MA. The results at 1.0 MA are in good agreement with predictions for first orbit alpha loss at 3.5 MeV. The 1.8 MA results, however, indicate a large anomalous loss of partially thermalized alphas at an energy ~30% below the birth energy and at a total fluence nearly an order of magnitude above the expected first orbit loss. This anomalous loss is not observed with the lost alpha scintillator detectors in DT plasmas but does resemble the anomalous `delayed' loss seen in DD plasmas. Several potential explanations for this loss process are examined. None of the candidate explanations proposed thus far are fully consistent with the anomalous loss observations
逃走アルファ粒子コレクタープローブは、1988年からTFTRで稼働している損失アルファ粒子シンチレータ検出器の結果を補完するために、トカマク核融合試験炉(TFTR)の重水素-トリチウム(DT)段階用に開発された。逃走アルファ粒子のエネルギー分布の測定は、アルファコレクター内に配置されたニッケル箔に注入されたアルファ粒子の飛程を測定することによって行われた。露光された試料は、プラズマ電流1.0 MAおよび1.8 MAでの4回のDTプラズマ放電について分析された。1.0 MAでの結果は、3.5 MeVでの第一軌道アルファ粒子損失の予測とよく一致している。しかしながら、1.8 MAでの結果は、生成エネルギーより約30%低いエネルギーでの部分的に熱化したアルファ粒子の大きな異常損失と、予想される第一軌道損失をほぼ一桁上回る全フルエンスを示している。この異常損失は、DTプラズマにおける損失アルファ粒子シンチレータ検出器では観測されないが、DDプラズマで見られる異常な「遅延」損失に類似している。この損失過程についてのいくつかの潜在的な説明が検討された。これまでに提案された候補の説明のいずれも、異常損失の観測結果と完全には一致しない。