AbstractA full-scale divertor support structure with hydraulic jacks was fabricated, and mechanical and seismic loading tests were carried out. This mock-up structure has four hydraulic jacks for locking the divertor plate and three jacks for lifting. The weight of the divertor plate model is 1.2 tons, similar to practical plate. The mechanical test results show that the divertor locking system provides high positioning tolerance within 0.3 mm and 0.2 mm in the toroidal and vertical directions respectively. To confirm the seismic response of the hydraulic cotter, a dynamic loading test was carried out. The fundamental frequency of 27 Hz is the mode of toroidal direction vibration, and is relatively high compared with the predominant earthquake frequencies. No damage of the hydraulic jacks appears under seismic loads. According to the results of mechanical and dynamic loading tests, the feasibility of the divertor support structure is verified.
実物大のダイバータ支持構造物に油圧ジャッキを備えたモックアップを製作し、機械的負荷試験および耐震負荷試験を実施した。このモックアップ構造体には、ダイバータ板を固定するための4基の油圧ジャッキと、持ち上げるための3基のジャッキが設置されている。ダイバータ板モデルの重量は1.2トンであり、実機の板と同等である。機械的試験の結果、ダイバータ固定システムは、トロイダル方向および垂直方向においてそれぞれ0.3mmおよび0.2mm以内の高い位置決め精度を提供することが示された。耐震応答を確認するため、動的負荷試験を実施した。基本周波数は27Hzであり、これはトロイダル方向の振動モードに対応するもので、主要な地震周波数と比較して比較的高い値である。地震負荷条件下において、油圧ジャッキに損傷は認められなかった。機械的負荷試験および動的負荷試験の結果に基づき、ダイバータ支持構造物の実現可能性が検証された。