The ITER Tokamak Complex is the civil structure that will host the ITER Tokamak and the largest part of the associated systems. The dimensions are 120 m × 80 m × 60 m, built mostly of concrete, with over one thousand penetrations. During ITER operation, a radiation field will spread throughout the complex from diverse radiation sources. It must be characterized to check the compliance with the limits for electronics allocation and human intervention. However, the production of radiation maps in the ITER Tokamak Complex is a task of paramount sophistication due to challenges to adequately model in MCNP the radiation sources involved. In this work, two important methodological upgrades are presented. First, a new MCNP model of the Tokamak Complex, conceived to be computationally stable while capturing a conservative representation of the baseline. Second, a novel approach to model the plasma source, called a mosaic source, allows an unprecedented degree of realism and accuracy in terms of capturing the port specificities. Both represent a step change in the capacity to produce ITER radiation maps with increased reliability, augmenting previous versions. Examples of partial radiation maps are provided considering both methodological upgrades.
ITERトカマク複合施設は、ITERトカマクと関連システムの大部分を収容する土木構造物である。その寸法は120 m × 80 m × 60 mであり、主にコンクリートで建設され、1000以上の貫通部を有する。ITER運転中、多様な放射線源から複合施設全体に放射線場が広がる。電子機器の配置制限および人間の介入に関する適合性を確認するためには、この放射線場を特性評価する必要がある。しかしながら、ITERトカマク複合施設における放射線マップの作成は、関連する放射線源をMCNPで適切にモデル化することの難しさから、極めて高度な課題である。本稿では、2つの重要な方法論的改良を提示する。第一に、ベースラインの保守的な表現を捉えつつ、計算的に安定するように設計されたトカマク複合施設の新しいMCNPモデルである。第二に、モザイク線源と呼ばれるプラズマ線源をモデル化する新しいアプローチであり、ポート固有の特性を捉える点において、前例のないレベルの現実性と精度を可能にする。これらは両方とも、従来版を拡張し、より高い信頼性でITER放射線マップを作成する能力における段階的変化を表す。両方の方法論的改良を考慮した部分的な放射線マップの例を提供する。