In the MEPhIST-0 tokamak, toroidal magnetic coil system is implemented as a single continuous toroidal solenoid. This design ensures synchronized operation of each segment of the solenoid and requires only one power supply line to operate. However, this configuration has the downside of introducing stray vertical and radial magnetic field components, which result from the inclination of the solenoid segments. Such stray fields can be measured using an electron beam, as previously demonstrated in experiments on T-15, TEXTOR, KSTAR, and SST-1. This paper describes the parameters of the experiment and presents the main results obtained from the MEPhIST-0 tokamak. Two experimental techniques for measuring the vertical magnetic field are discussed: one with a change in the current direction in the toroidal solenoid and one without. The ratio of the stray vertical field to the toroidal field was found to be approximately 0.5%. The conducted experiments highlight the necessity of compensating for the stray vertical field using additional poloidal coils.
MEPhIST-0トカマクにおいて、トロイダル磁場コイルシステムは単一の連続トロイダルソレノイドとして実装されている。この設計により、ソレノイドの各セグメントの同期動作が保証され、動作に必要な電源ラインは1本のみである。しかしながら、この構成には、ソレノイドセグメントの傾斜に起因する迷走垂直磁場成分および径方向磁場成分が導入されるという欠点がある。このような迷走磁場は、T-15、TEXTOR、KSTAR、SST-1における実験でこれまでに実証されたように、電子ビームを用いて測定することが可能である。本論文では、MEPhIST-0トカマクにおける実験パラメータについて述べ、得られた主な結果を示す。迷走垂直磁場の測定には2つの実験手法を用いた:トロイダルソレノイドの電流方向を変化させる方法と、変化させない方法である。迷走垂直磁場とトロイダル磁場の比は約0.5%であることが判明した。実施した実験により、追加のポロイダルコイルを用いた迷走磁場の補償の必要性が明らかになった。