Design of ITER neutron yield monitor using microfission chambers

T Nishitani, K Ebisawa, T Iguchi, T Matoba1997年Fusion Engineering and DesignIF 1.7出版社

AbstractWe propose a microfission chamber system which will be installed near the first wall region of ITER as the neutron yield monitor. This system has a wide dynamic range of 1010 with a temporal resolution of 1 ms and is easily calibrated by a neutron transport calculation. The 234U (80%) + 235U (20%) fission chamber, the lifetime of which is about four times longer than that of the 235U chamber, can be used in ITER for one third of the ITER lifetime. We expect that these detectors will be operated in a high magnetic field near the first wall of ITER. Four sets of the detectors will be installed in the large side port and three blanket modules. Techniques for the replacement of those detectors are discussed.

日本語訳

我々は、ITERの第一壁領域近傍に設置される中性子収量モニタとして、マイクロ核分裂チェンバーシステムを提案する。本システムは、10¹⁰の広いダイナミックレンジと1 msの時間分解能を有し、中性子輸送計算により容易に校正が可能である。²³⁴U(80%)+²³⁵U(20%)核分裂チェンバーは、²³⁵Uチェンバーの約4倍の寿命を有し、ITERの運転寿命の約3分の1の期間使用することができる。これらの検出器は、ITERの第一壁近傍の高磁場環境下で動作することが期待される。4セットの検出器が大型サイドポートおよび3つのブランケットモジュールに設置される。これらの検出器の交換手法について議論する。

装置

iter高精度(タイトル一致)

wiki

ITERNeutron yield
この論文にはまだAI要約がありません。

関連論文

Characterization of a diamond detector to be used as neutron yield monitor during the in-vessel calibration of JET neutron detectors in preparation of the DT experiment

2016Fusion Engineering and Design

Features of fusion power measurements in next-generation magnetic plasma confinement experiments

2026Nuclear Fusion

14 MeV calibration of JET neutron detectors—phase 1: calibration and characterization of the neutron source

2018Nuclear Fusion

Neutronic analysis for in situ calibration of ITER in-vessel neutron flux monitor with microfission chamber

2013Fusion Engineering and Design

14 MeV calibration of JET neutron detectors—phase 2: in-vessel calibration

2018Nuclear Fusion

In-situ calibration of neutron flux monitor for HL-3 tokamak

2026Nuclear Fusion

Effect of thermal neutrons on fusion power measurement using the microfission chamber in ITER

2011Fusion Engineering and Design

Engineering design of the ITER invessel neutron monitor using micro-fission chambers

2007Fusion Engineering and Design

Status of ITER neutron diagnostic development

2005Nuclear Fusion

Development of 14 MeV neutron spectrometer for fusion experimental reactor

1997Fusion Engineering and Design