Intrinsic error field on EAST is measured using the 'compass scan' technique with different n = 1 magnetic perturbation coil configurations in ohmically heated discharges. The intrinsic error field measured using a non-resonant dominated spectrum with even connection of the upper and lower resonant magnetic perturbation coils is of the order and the toroidal phase of intrinsic error field is around . A clear difference between the results using the two coil configurations, resonant and non-resonant dominated spectra, is observed. The 'resonant' and 'non-resonant' terminology is based on vacuum modeling. The penetration thresholds of the non-resonant dominated cases are much smaller than that of the resonant cases. The difference of penetration thresholds between the resonant and non-resonant cases is reduced by plasma response modeling using the MARS-F code.
EASTにおける固有誤差磁場は、オーム加熱放電において異なるn = 1磁気摂動コイル構成を用いた「コンパススキャン」手法により測定される。上部および下部共鳴磁気摂動コイルの偶数接続を伴う非共鳴支配スペクトルを用いて測定された固有誤差磁場は、オーダー であり、固有誤差磁場のトロイダル位相は 程度である。2つのコイル構成、すなわち共鳴および非共鳴支配スペクトルを用いた結果の間には明確な差異が観測される。「共鳴」および「非共鳴」という用語は真空モデリングに基づくものである。非共鳴支配の場合の侵入閾値は、共鳴の場合のそれよりもはるかに小さい。共鳴および非共鳴の場合の侵入閾値の差異は、MARS-Fコードを用いたプラズマ応答モデリングによって低減される。