AbstractThree dimensional neutronic analysis was performed to determine effects of radiation streaming through ITER ports with installed shield plugs and different diagnostic equipment. Studied were Neutral Particle Analyser (NPA), Neutron Camera Array and LIDAR plasma diagnostic in upper and midplane ports. The purpose of the analysis was an estimation of nuclear radiation level in the vicinity of ports due to radiation streaming, radiation responses in TF and PF coils, activation and dose rate levels. Some study was performed to estimate radiation level at locations of diagnostic sensors in NPA behind ITER biological shield. All radiation transport calculations were carried out using 3-dimensional code MCNP-4A with pointwise FENDL-1 library. Activation calculations were performed using FISPACT inventory code. The obtained results can be used in designing of the studied diagnostics.
三次元中性子解析を実施し、ITERポートに設置された遮蔽プラグおよび異なる診断装置を通る放射線ストリーミングの影響を決定した。対象としたのは、上部および中間ポートにおける中性粒子分析装置(NPA)、中性子カメラアレイ、およびLIDARプラズマ診断装置である。解析の目的は、放射線ストリーミングによるポート近傍の核放射線レベルの推定、TFおよびPFコイルにおける放射線応答、ならびに放射化および線量率レベルの評価であった。また、ITER生物学的遮蔽の背後にあるNPA内の診断センサー位置における放射線レベルの推定も一部実施した。すべての放射線輸送計算は、点データFENDL-1ライブラリを備えた三次元コードMCNP-4Aを用いて実施した。放射化計算は、FISPACTインベントリコードを用いて実施した。得られた結果は、対象とした診断装置の設計に活用することができる。