AbstractTwo-dimensional shielding analyses have been performed on the maintenance and test module mid-plane ports in the International Thermonuclear Experimental Reactor (ITER). Nuclear responses in the toroidal field (TF) and poloidal field (PF) coils around these ports have been calculated. Shield plugs with 20-mm-wide gaps between the blanket modules exist in both ports. In the case of the test module port, they are installed at the back of a 500-mm-thick test module. In order to satisfy design limits, 540- and 150-mm-thick shield plugs are required for the maintenance and the test module port, respectively. In addition, nuclear responses as a function of the gap width have also been estimated. In the case of the 50-mm-wide gap, it is found that 750 and 390-mm-thick shield plugs are required for the maintenance and test module ports, respectively.
国際熱核融合実験炉(ITER)の保守モジュールおよび試験モジュールのポート中間面において、二次元遮蔽解析が実施された。これらのポート周辺のトロイダル磁場(TF)コイルおよびポロイダル磁場(PF)コイルにおける核的応答が計算された。ブランケットモジュール間の20mm幅のギャップを有する遮蔽プラグが、両方のポートに存在する。試験モジュールポートの場合、それらは500mm厚の試験モジュールの背後に設置される。設計限界を満たすためには、保守モジュールポートには540mm厚、試験モジュールポートには150mm厚の遮蔽プラグがそれぞれ必要である。さらに、ギャップ幅の関数としての核的応答も評価された。50mm幅のギャップの場合、保守モジュールポートには750mm厚、試験モジュールポートには390mm厚の遮蔽プラグがそれぞれ必要であることが判明した。