The present paper addresses the issue of particle recirculation in discharges where low-energy flux to ergodic divertor target plates is achieved in highly-radiating detached ohmic plasmas. Plasma temperature and particle flux are measured by flush-mounted probes in the divertor plates and by an upstream fast scanning Mach probe. The scalings with core density of the ion flux and electron temperature are well described by the simple two-point model used in axisymmetric poloidal divertors. The detachment signature is a pressure drop that occurs when the edge temperature falls below 10 eV. The parallel ion flux gradient is always positive, indicating that recombination is unlikely to play an important role in detachment. Visible spectroscopy of a neutralizer plate shows that attainment of cold detached plasmas near the density limit coincides with an abrupt increase of fuelling efficiency for both deuterium and impurities. A feedback algorithm based on real-time Langmuir probe measurements has been developed to monitor detachment and avoid disruptions.
本論文は、高放射非接触(デタッチド)オーミックプラズマにおいて、エルゴディックダイバータのターゲット板への低エネルギー粒子束が実現される放電における粒子再循環の問題を扱う。プラズマ温度と粒子束は、ダイバータ板に埋め込まれたフラッシュマウントプローブと、上流側の高速走査マッハプローブによって測定される。イオン束と電子温度のコア密度に対するスケーリング則は、軸対称ポロイダルダイバータに用いられる単純な二点モデルによってよく記述される。非接触状態の特徴は、周辺温度が10 eV以下に低下した際に生じる圧力降下である。平行イオン束勾配は常に正であり、これは再結合が非接触状態において重要な役割を果たす可能性が低いことを示している。ニュートラライザープレートの可視分光測定により、密度限界付近での低温非接触プラズマの達成は、重水素および不純物の両方に対する燃料補給効率の急激な増加と一致することが示された。非接触状態を監視し、ディスラプションを回避するためのフィードバックアルゴリズムが、リアルタイムラングミュアプローブ測定に基づいて開発された。