An imaging neutral particle analyser (INPA) diagnostic has been installed and commissioned at the ASDEX Upgrade (AUG) tokamak. The AUG INPA diagnostic provides energy and radially resolved measurements of the fast-ion (FI) distribution, complementing the existing set of diagnostic which measure the confined FI population. To this end, it analyses charge exchange (CX) neutrals produced in reactions between FI and neutrals injected by a neutral beam injector. These CX neutrals are ionised by a 20 nm carbon foil and deflected towards a scintillator by the machine magnetic field. The use of a scintillator as active component allows us to cover the whole plasma radial range with an energy resolution of 9 keV and a spatial of 3 cm for 93 keV deuterons. First measurements demonstrate the high sensitivity of the INPA diagnostic to different AUG fast-ion distribution functions, from NBI and ion-cyclotron resonance heating origin, and show good agreement with the synthetic diagnostic.
ASDEX Upgrade(AUG)トカマクにおいて、イメージング中性粒子分析器(INPA)診断装置の設置とコミッショニングが実施された。AUG INPA診断装置は、閉じ込められた高速イオン(FI)集団を測定する既存の診断装置群を補完する、高速イオン(FI)分布のエネルギー分解および径方向分解測定を提供する。この目的のため、中性粒子ビーム入射装置によって入射された中性粒子とFIとの間の反応で生成される荷電交換(CX)中性粒子を分析する。これらのCX中性粒子は、20 nmのカーボンフォイルによって電離され、装置の磁場によってシンチレータに向けて偏向される。シンチレータを活性成分として使用することで、93 keV重水素に対するエネルギー分解能9 keV、空間分解能3 cmでプラズマの全径方向範囲をカバーすることが可能となる。最初の測定結果は、INPA診断装置がNBIおよびイオンサイクロトロン共鳴加熱起源の異なるAUG高速イオン分布関数に対して高い感度を示し、合成診断と良好な一致を示すことを実証している。