Disruptions in Alcator C-Mod can generate large eddy currents in the highly conducting vacuum vessel and internal structures, including a significant poloidal component due to halo currents. In order to understand better the stresses arising from the resulting J*B forces, Alcator C-Mod has been fitted with a comprehensive set of sensors to measure the spatial distribution and temporal behaviour of the halo currents. It is found that they are toroidally asymmetric, with a typical peaking factor of 2. The asymmetric pattern usually rotates toroidally at a few kilohertz, thus ruling out first wall non-uniformities as the cause of the asymmetry. Analysis of the information compiled in the C-Mod disruption database indicates that the maximum halo current during a disruption scales roughly as either Ip2/Bphi or Ip/q95, but that there is a large amount of variation that is not yet understood
アルカトールC-Modにおけるディスラプションは、高い導電性を有する真空容器および内部構造物に大きな渦電流を発生させることがあり、ハロー電流による有意なポロイダル成分も含まれる。結果として生じるJ*B力による応力をよりよく理解するため、アルカトールC-Modには、ハロー電流の空間分布と時間的挙動を測定するための包括的なセンサー群が設置されている。ハロー電流はトロイダル方向に非対称であり、典型的なピーキング係数は2であることが判明した。非対称パターンは通常、数キロヘルツでトロイダル方向に回転しており、したがって非対称性の原因が第一壁の不均一性ではないことが示される。C-Modディスラプションデータベースに蓄積された情報の解析により、ディスラプション中の最大ハロー電流はおおよそIp2/BphiまたはIp/q95に比例してスケーリングすることが示されるが、まだ理解されていない大きな変動が存在する。