The JT-60 neutral beam injector consists of 14 beam line units and injects a rated power of 20 MW with an energy level of 70–100 keV for beam pulses up to 10 s. The total handling power of ion and/or neutral beams in the beam line unit amounts to as much as 8 MW per unit for a beam extraction of 100 keV/80 A, though each unit delivers a neutral beam power of about 1.4 MW. Accordingly, the beam stop components have to receive a high heat load. Another difficulty is that the beam stops must receive quasi continuous heat loadings for up to 10 s. The design procedures and the measured characteristics of the beam stop components irradiated with the beam are described. In the maximum rated operation of a 100 keV/80 A beam extraction for a beam pulse up to 10 s, the incident power to the beam stop components in the beam line unit has roughly reached the design value, and every component works well now.