AbstractThe motional Stark effect (MSE) diagnostic has emerged as the most reliable technique for the measurement of q profiles in tokamaks equipped with neutral beams. In the DIII-D tokamak, two separate eight-channel MSE instruments are utilized, giving 16 radial measurements. The viewing geometry for each instrument is designed to optimize the radial resolution (1.5 cm < δR < 6 cm) over the measurement range. Dual-frequency polarization modulators combined with lock-in detection provide a maximum signal-to-noise ratio with a time response of about 1 ms. Special consideration has gone into the design of the collection optics to minimize undesirable polarization effects on reflectors and Faraday roation in lenses. Examples of data from negative central magnetic shear, VH-mode and sawtoothing discharges highlight the capabilities of the DIII-D MSE diagnostic system.
運動スタルク効果(MSE)診断は、中性粒子ビームを備えたトカマクにおけるqプロファイル測定の最も信頼性の高い手法として確立されている。DIII-Dトカマクでは、2つの独立した8チャンネルMSE装置が使用され、合計16の動径方向測定が行われる。各装置の視野幾何学は、測定範囲全体にわたって動径分解能(1.5 cm < δR < 6 cm)を最適化するように設計されている。二周波偏光変調器とロックイン検出を組み合わせることで、約1 msの時間応答で最大の信号対雑音比が達成される。集光光学系の設計には特に注意が払われ、反射鏡における不要な偏光効果とレンズにおけるファラデー回転を最小化している。負の磁気シア、VHモード、および鋸歯状振動放電からのデータ例は、DIII-D MSE診断システムの能力を示している。