Direct loss of energetic electrons during lower hybrid current drive in JT-60U is identified through measurements of X-ray signals from the divertor plates. It is found that the lost power decreases with increasing electron density and with increasing launched wave N|| and is characterized by the slowing down time of the electrons accelerated by lower hybrid waves. At ne ~ 0.5 × 1019 m-3 and N|| ~ 1.4, about 5-10% of the injected power is lost through the energetic electrons; the maximum current drive efficiency is obtained at a plasma current of 1.2 MA in JT-60U. It is also found that the confinement of high energy electrons is improved by increasing the plasma current. These results suggest that the power lost directly through energetic electrons will be negligible in ITER in steady state operation
JT-60Uにおける低混波電流駆動中の高エネルギー電子の直接損失が、ダイバータ板からのX線測定によって同定された。損失パワーは、電子密度の増加および入射波のN||の増加とともに減少し、低混波により加速された電子の減速時間によって特徴づけられることが見出された。ne 〜 0.5 × 10^19 m^-3、N|| 〜 1.4において、入射パワーの約5〜10%が高エネルギー電子を介して損失される。最大の電流駆動効率は、JT-60Uにおいてプラズマ電流1.2 MAで得られた。また、高エネルギー電子の閉じ込めは、プラズマ電流の増加とともに改善されることが見出された。これらの結果は、定常運転におけるITERでは、高エネルギー電子を介した直接損失は無視できる程度になることを示唆している。