AbstractAn evaluation method of the magnetic damping effect and a method to determine the conditions for a reduced scale magnetic damping test of fusion reactor first wall are described. The coupling intensity parameter is used for the evaluation method because it has the potential to evaluate the magnetic damping effect. The thickness and the steady magnetic field required in the reduced tests are obtained to maintain two parameters unchanged, namely the coupling intensity parameter and the ratio of time constants of eddy current and structure, using finite element analysis and the solution of the coupled eigenvalue. To verify the scaling method, experiments and numerical analyses of a plate are performed for various scale factors. Good agreement between the displacement responses of the original and reduced configurations is obtained. The steady magnetic field of the reduced scale test can be decreased using copper or aluminum alloy instead of austenitic stainless steel.
核融合炉第一壁の磁気減衰効果の評価方法と、縮小スケール磁気減衰試験の条件決定方法について述べる。結合強度パラメータは磁気減衰効果を評価する可能性を有するため、評価方法に用いる。縮小試験に必要な板厚と定常磁場は、結合強度パラメータと渦電流と構造体の時定数比の2つのパラメータを不変に保つことにより求められ、有限要素解析と連成固有値解析を用いる。スケーリング手法の検証のため、様々なスケール因子に対して平板の実験と数値解析を行う。原寸と縮小モデルの変位応答は良好な一致を示す。オーステナイト系ステンレス鋼の代わりに銅またはアルミニウム合金を用いることで、縮小スケール試験の定常磁場を低減できる。