The paper presents a comparison of the main characteristics and experimental results obtained in plasma focus (PF) experiments in the POSEIDON 500 kJ facility in Stuttgart and the PF-360 kJ device in Świerk. Parameters of various electrodes and insulators are given, and studies on the evolution of the discharges are summarized. Selected data on X-ray, ion and neutron emission are given. Also presented are recent experimental results — a maximum neutron yield of up to 2.5 × 1011 for 500 kJ/80 kV runs with a new ceramic insulator in POSEIDON and an average neutron yield of 1.2 × 1011 for operation at 171 kJ/36 kV in PF-360. Particular attention is paid to the neutron scaling and the saturation effects observed at higher energy and current levels. Proposals are made for new experimental studies which can facilitate further progress in PF research.
本論文は、シュトゥットガルトのPOSEIDON 500 kJ施設およびシフィエルクのPF-360 kJ装置におけるプラズマフォーカス(PF)実験で得られた主要な特性と実験結果の比較を示すものである。各種電極および絶縁体のパラメータを示し、放電の進展に関する研究を要約する。X線、イオン、中性子の放出に関する選定データを示す。また、最近の実験結果として、POSEIDONにおける新型セラミック絶縁体を用いた500 kJ/80 kV運転での最大中性子収量2.5 × 10¹¹、およびPF-360における171 kJ/36 kV運転での平均中性子収量1.2 × 10¹¹を示す。特に、より高いエネルギーおよび電流レベルで観測された中性子スケーリングと飽和効果に注目する。PF研究のさらなる進展を促進し得る新たな実験研究の提案を行う。