Massive gas injection rapid shutdown experiments have been conducted on the Alcator C-Mod tokamak using two toroidally separated gas injectors, in order to investigate the effect of multiple gas injection locations on the toroidal asymmetry in the radiated power. Toroidal radiation asymmetry is diagnosed by an array of six single-channel photodiodes mounted on the vessel wall. The presence of magnetohydrodynamic (MHD) activity is diagnosed using an array of magnetic pickup (Mirnov) coils, mounted on stalks on the vessel wall. Scans were conducted of the relative timing between the two jets, of the 95th percentile safety factor, and of the plasma elongation. It is observed that firing the two gas jets so that the injected impurities arrive at the plasma at nearly the same time produced an increase in the toroidal radiation asymmetry. In addition, the radiation asymmetry in the thermal quench phase correlates with the growth rate of low toroidal mode number MHD modes, indicating that these mode(s) are playing a role in setting the radiation asymmetry.
アルカーターC-Modトカマクにおいて、2つのトロイダル方向に分離されたガス入射器を用いた大量ガス入射急速停止実験を実施し、複数のガス入射位置が放射パワーのトロイダル非対称性に及ぼす影響を調査した。トロイダル放射非対称性は、容器壁に取り付けられた6つのシングルチャンネルフォトダイオードのアレイによって診断される。磁気流体力学(MHD)活動の存在は、容器壁のステーク上に取り付けられた磁気ピックアップ(ミルノフ)コイルのアレイを用いて診断される。2つのジェット間の相対タイミング、95パーセンタイル安全係数、およびプラズマ伸長度について走査を行った。2つのガスジェットを、注入された不純物がほぼ同時にプラズマに到達するように発射すると、トロイダル放射非対称性が増加することが観測された。さらに、熱クエンチ段階における放射非対称性は、低トロイダルモード数MHDモードの成長率と相関しており、これらのモードが放射非対称性の形成に役割を果たしていることを示している。