Transport simulations of high density scenarios of ITER and other reactor-grade devices require a scaling law for the effective heat diffusivity, χ, in the ELMy H-mode regime. A comprehensive empirical scaling, χH98, compatible with the ITER reference scaling, ITERH-98P(y, 2), for the thermal energy confinement time has been set up. It follows from a power law ansatz for χ and integration of the single-fluid energy equation and recovers all the exponents of the global confinement law. The dependences on temperature and temperature gradient are consistent with the power degradation of confinement and the experimental χ profiles. The χH98 scaling is validated by JET, DIII-D, ASDEX Upgrade and ASDEX discharges covering a wide parameter range. Simulations of the inductive scenario of ITER with χH98 yield an energy confinement time which agrees with the global scaling prediction.
ITERや他の炉級装置の高密度シナリオの輸送シミュレーションには、ELMy Hモード領域における有効熱拡散係数χのスケーリング則が必要である。熱エネルギー閉じ込め時間に関するITER参照スケーリング則ITERH-98P(y, 2)と互換性のある包括的な経験的スケーリング則χH98が構築された。これは、χに対するべき乗則の仮定と単一流体エネルギー方程式の積分から導かれ、全体の閉じ込め則のすべての指数を再現する。温度および温度勾配への依存性は、閉じ込めのパワー劣化および実験的なχ分布と整合的である。χH98スケーリング則は、広いパラメータ範囲をカバーするJET、DIII-D、ASDEX UpgradeおよびASDEXの放電によって検証されている。χH98を用いたITERの誘導シナリオのシミュレーションは、全体のスケーリング予測と一致するエネルギー閉じ込め時間を与える。