The ability to capture the isotope mass scaling of core confinement seen in experiment is validated with JETTO-TGLF for low power JET-ILW discharges across H, D and T. The cases analysed include Ohmic discharges spanning the linear and saturated Ohmic confinement regimes as well as a trio of L-modes. The TGLF saturation rules SAT1–SAT3 are seen to predict a similar isotope scaling across both the ITG- and TEM-dominated discharges simulated, despite for the latter case the inclusion of the TEM branch of SAT3. The models demonstrate good agreement with experiment for the scaling between D and T plasmas, however a discrepancy is observed for H in the ITG-dominated discharges of higher density, as well as a systematic overprediction of the confinement time on the order of 20% in most cases. A retuned version of the SAT3 model, which was fit to better recreate fluxes close to the transport threshold, is seen to improve the magnitude of confinement predictions across all shots owing to an increased transport stiffness. This retuning was not seen to influence the confinement isotope scaling however, and possible transport mechanisms responsible for the continued discrepancy of higher density Ohmic and L-mode discharges in H are discussed.
実験で見られる中心閉じ込めの同位体質量スケーリングを再現する能力は、H、D、Tにわたる低パワーのJET-ILW放電に対してJETTO-TGLFを用いて検証される。解析されたケースには、線形および飽和オーミック閉じ込め領域に及ぶオーミック放電と、3つのLモードが含まれる。TGLF飽和則SAT1–SAT3は、シミュレーションされたITG優勢およびTEM優勢の両方の放電にわたって同様の同位体スケーリングを予測することが見られる。後者の場合にはSAT3のTEM分枝を含むにもかかわらずである。モデルはDプラズマとTプラズマの間のスケーリングについては実験と良い一致を示すが、より高密度のITG優勢放電におけるHについては不一致が観察され、またほとんどの場合において閉じ込め時間の約20%の系統的な過大予測が見られる。輸送閾値近傍のフラックスをよりよく再現するようにフィッティングされたSAT3モデルの再調整版は、輸送スティフネスの増加により、全ショットにわたって閉じ込め予測の大きさを改善することが見られる。しかしながら、この再調整は閉じ込めの同位体スケーリングには影響を与えないことが見られ、Hにおける高密度オーミックおよびLモード放電の継続的な不一致の原因となる可能性のある輸送機構について議論される。