Impact of window temperature variations on ITER toroidal interferometer and polarimeter (TIP) measurements

T Akiyama, M A Van Zeeland, D K Finkenthal, M LeSher, R Finden, P Trost, A Gattuso, S Miranda, M Groh, Marc-André de Looz2025年11月Plasma Physics and Controlled FusionIF 2.2出版社

The toroidal interferometer and polarimeter (TIP) is one of the primary electron density diagnostics on ITER. To meet measurement requirements over several thousand seconds, environmental factors such as changes in the window temperature, air temperature, and humidity, which can cause uncompensated phase drifts, must be minimized. This paper reports measurements of the phase shift induced by ZnSe and BaF2 windows as their temperature is varied utilizing the TIP prototype. To accomplish these measurements, test pieces of BaF2 and ZnSe are placed in a small oven that is located in one leg of the 10.59/5.22 µm two-color interferometer TIP prototype. The oven temperature was varied from room temperature to ∼90 °C, which is slightly higher than the expected window temperatures on ITER. The vibration compensated phase shifts measured for these two materials are dϕvc/dT/L = 0.0121 and −0.275 deg. °C−1 cm−1 for BaF2 and ZnSe, respectively. From these measurements, it was concluded that temperature variations of the environmental/secondary confinement barrier window and primary vacuum window have to be suppressed within approximately 1 °C and 2 °C, respectively, in order to passively meet the electron density measurement requirements in ITER.

装置

iter高精度(タイトル一致)

wiki

ITERInterferometer

AIによる論文要約

窓温度変動がITERトロイダル干渉計・偏光計(TIP)測定に与える影響
JAITERの計測システム設計者やプラズマ診断を学ぶ学生。窓温度が測定精度に与える影響を理解するため。#ITER #プラズマ診断 #干渉計 #偏光計 #窓温度
LLM向け: {"Title": "Impact of window temperature variations on ITER toroidal interferomet…

ITERの電子密度計測に用いられるトロイダル干渉計・偏光計(TIP)は、窓の温度変化による位相ドリフトの影響を受けます。本研究では、TIPプロトタイプを使用し、ZnSeとBaF2の窓材の温度を室温から90°Cまで変化させて位相シフトを測定しました。その結果、BaF2ではdϕvc/dT/L = 0.0121 deg/°C/cm、ZnSeでは-0.275 deg/°C/cmの位相変化率が得られました。ITERの計測要求を満たすには、環境・第二閉じ込めバリア窓の温度変動を約1°C、第一真空窓を約2°C以内に抑える必要があります。この研究は、長時間計測における温度管理の重要性を示しています。

関連論文

Tests of a two-color interferometer and polarimeter for ITER density measurements

2017Plasma Physics and Controlled Fusion

Electron kinetic effects on interferometry and polarimetry in high temperature fusion plasmas

2013Nuclear Fusion

Electron density and q profile measurements with the far-IR interferometer-polarimeter on the TEXTOR tokamak

1997Fusion Engineering and Design

High-frequency measurement of the interferometric phase, the Faraday rotation, and the Cotton-Mouton effect with a single detector in a far-infrared interferometer-polarimeter

2022Plasma Physics and Controlled Fusion

Development of a wide bandwidth heterodyne dispersion interferometer for electron density measurement of atmospheric pressure plasmas

2025Plasma Physics and Controlled Fusion

Initial measurements of plasma current and electron density profiles using a polarimeter/interferometer (POINT) for long pulse operation in EAST (invited)

2016Review of Scientific Instruments

Integrated reflectometer-interferometer system for plasma density profile measurement

1998Plasma Physics and Controlled Fusion

Consideration of density measurement using toroidal interferometer and polarimeter on JA DEMO

2026Fusion Engineering and Design

Electron temperature measurements with high time resolution in RFX

1996Plasma Physics and Controlled Fusion

Relativistic effects on reconstruction of density profiles via reflectometry in ITER and potential for electron temperature measurements

2007Plasma Physics and Controlled Fusion