During deuterium campaigns on the heliotron large helical device (LHD), ITER pressure gauges with different cathode materials were used to measure the neutral pressure in the sub-divertor region. Throughout these campaigns, it was observed that the performance of a LaB6 cathode was unsatisfactory during deuterium operation. Conversely, measurements taken with pressure gauges with a ZrC cathode performed well throughout the deuterium pulses. The ITER pressure gauge with the ZrC cathode could be operated with a very high electron current of 800 µA, thus improving the lower detection limit of the neutral pressure in LHD. With this design it was also possible to avoid jumps in the ion current within strong magnetic fields, improving the accuracy of the measurement from 15% uncertainty to 5%. These features allowed very precise neutral pressure measurements to be made in a fusion device with magnetic confinement. The problems with the lifetime of the ZrC cathode reported in Mackel et al (2023 Fusion Eng. Des.189 113439) were not relevant here, as the total runtime in the magnetic field was about 60 h, less than the expected lifetime of the cathode of 350 h.
重水素キャンペーン中、ヘリオトロン型大型ヘリカル装置(LHD)において、異なる陰極材料を備えたITER圧力計を用いて、サブダイバータ領域の中性ガス圧力を測定した。これらのキャンペーンを通じて、LaB6陰極の性能は重水素運転中に不満足であることが観察された。逆に、ZrC陰極を備えた圧力計による測定は、重水素パルス全体にわたって良好に機能した。ZrC陰極を備えたITER圧力計は、800 µAという非常に高い電子電流で動作させることができ、これによりLHDにおける中性ガス圧力の下限検出限界が改善された。この設計により、強磁場中でのイオン電流のジャンプを回避することも可能となり、測定精度が不確かさ15%から5%に改善された。これらの特徴により、磁気閉じ込め核融合装置において非常に精密な中性ガス圧力測定が可能となった。Mackelら(2023 Fusion Eng. Des. 189 113439)で報告されたZrC陰極の寿命に関する問題は、ここでは該当しなかった。なぜなら、磁場中での総運転時間は約60時間であり、陰極の期待寿命である350時間未満だったからである。