The EMC3-Eirene code package was applied for the first time to simulate the edge plasma in an ASDEX Upgrade discharge, in which the newly installed magnetic perturbation (MP) coils were used to mitigate edge-localized modes (ELMs). Two different points in time during this discharge were simulated, the ELM-mitigated phase after turning-on of the MP coils and, as a reference, the ELMy H-mode phase before. The results were compared with the measurements of various edge and divertor diagnostics. Assuming the main chamber profiles to be shifted by 15 mm with respect to their calibrated positions, an agreement within a factor of 2 was found between the main chamber profiles outside the separatrix and those at the outer divertor target. The most important result is the observation of several maxima and minima in the particle flux and in particular in the power deposition pattern of both the simulation and the experiment for the case with MPs, an effect also known as strike-point splitting.
EMC3-Eireneコードパッケージは、新たに設置された磁気摂動(MP)コイルが周辺局在モード(ELM)を緩和するために使用されたASDEX Upgrade放電における周辺プラズマをシミュレートするために初めて適用された。この放電中の2つの異なる時点、すなわちMPコイル投入後のELM緩和位相と、参照としてのその前のELMy Hモード位相がシミュレートされた。結果は、様々な周辺およびダイバータ診断の測定値と比較された。主チャンバーのプロファイルが較正位置に対して15mmずれていると仮定すると、セパラトリックスの外側の主チャンバープロファイルと外側ダイバータターゲットのプロファイルの間で2倍以内の一致が見られた。最も重要な結果は、MPがある場合の粒子束、特に電力堆積パターンにおいて、シミュレーションと実験の両方で複数の極大値と極小値が観測されたことであり、これはストライク点分割としても知られる効果である。