The injection performance of the negative-ion based NBI (N-NBI) system for JT-60U has been improved by correcting beamlet deflection and improving spatial uniformity of negative ion production. Beamlet deflection at the peripheral region of the grid segment due to the distorted electric field at the bottom of the extractor has been observed. This was corrected by modifying the surface geometry at the extractor to form a flat electric field. Moreover, beamlet deflection due to beamlet–beamlet repulsion caused by space charge was also compensated for by extruding the edge of the bottom extractor. This resulted in a reduction of the heat loading on the NBI port limiter. As a result of the improvement above, continuous injection of a 2.6 MW H0 beam at 355 keV has been achieved for 10 s. Thus, long pulse injection up to the nominal pulse duration of JT-60U was demonstrated. This has opened up the prospect of long pulse operation of the negative-ion based NBI system for a steady-state tokamak reactor. So far, a maximum injection power of 5.8 MW at 400 keV, with a deuterium beam, and 6.2 MW at 381 keV, with a hydrogen beam, have been achieved in the JT-60U N-NBI. Uniformity of negative ion production was improved by tuning the filament emission current so as to direct more arc power into the region where less negative ion current was extracted.
Study of increasing the beam power on the negative ion based neutral beam injector for JT-60 U