AbstractConstruction of the 500 keV negative-ion-based NBI system (N-NBI) with its maximum capability of 10 MW and 10 s for NB current drive and plasma core heating in high-density plasmas in JT-60 was completed in March 1996. The neutral beam injection into JT-60 with N-NBI has been performed since then. One of the key issues in the injection was how to control the bending magnetic field for residual ion beams. In N-NBI for JT-60, a stray magnetic field from the tokamak was actively used for bending of the residual ion beams. Combination of the stray magnetic field from JT-60 and the magnetic field of the deflecting coils was controlled sufficiently to successfully deposit residual ion beams at a constant point on the ion dump surface. The deposited positive and negative beam profiles on the ion dump were measured with an array of thermocouples brazed on the dump surface. This report describes the performance test of bending the residual ion beams and the measurement of the heat load on the ion dump for JT-60 N-NBI experiments.
500 keV負イオン源NBIシステム(N-NBI)は、JT-60における高密度プラズマ中のNB電流駆動およびプラズマ中心部加熱を目的とし、最大出力10 MW、10秒間の運転が可能なシステムとして1996年3月に完成した。以降、N-NBIによるJT-60への中性粒子ビーム入射が実施されている。入射における重要課題の一つは、残留イオンビームの偏向磁場の制御であった。JT-60のN-NBIでは、トカマクからの迷走磁場が残留イオンビームの偏向に積極的に利用された。JT-60からの迷走磁場と偏向コイルの磁場の組み合わせを十分に制御することにより、残留イオンビームをイオンダンプ表面上の一定点に安定的に堆積させることに成功した。イオンダンプ上に堆積した正および負のビームプロファイルは、ダンプ表面にろう付けされた熱電対アレイを用いて測定された。本報告書は、JT-60 N-NBI実験における残留イオンビームの偏向性能試験とイオンダンプ上の熱負荷測定について述べるものである。