AbstractAs an R&D task of the ITER engineering design activities (EDA), we carried out the irradiation tests on the basic materials of transmission components such as ceramics, windows, fiber optics and mirrors, and in-vessel diagnostics sensors such as magnetic probes and bolometers. Ceramics will be used as general insulating materials. Here we investigated the radiation induced conductivity (RIC) of ceramics for 14 MeV neutrons. Optical elements are the most sensitive to radiation damages among the transmission components. Radiation induce transmission loss of window materials and fiber optics have been measured in the Japan material testing reactor (JMTR). Off line irradiation tests were carried out for molybdenum corner cube reflector (CCR) and gold coated mirrors in JMTR also. Fourteen MeV-neutron-induce luminescence of window material was evaluated in the fusion neutronics source (FNS). Bolometers should be installed inside the vacuum vessel to measure the radiation losses in the infra red to soft X-ray range. We demonstrated the performance of the JT 60 type bolometer under 60Co gamma-rays.
ITER工学設計活動(EDA)のR&Dタスクとして、セラミックス、窓材、光ファイバー、ミラーなどの伝送部品の基本材料と、磁気プローブやボロメータなどの真空容器内計測センサーについて照射試験を実施した。セラミックスは一般的な絶縁材料として使用される。ここでは、14MeV中性子に対するセラミックスの照射誘起導電度(RIC)を調査した。光学素子は伝送部品の中で放射線損傷に最も敏感である。窓材料と光ファイバーの放射線誘起透過損失を、JMTR(材料試験炉)で測定した。モリブデン製コーナーキューブリフレクタ(CCR)と金コーティングミラーについても、JMTRにおいてオフライン照射試験を実施した。窓材料の14MeV中性子誘起発光をFNS(核融合中性子源)で評価した。ボロメータは、赤外から軟X線領域の放射損失を測定するために真空容器内に設置されるべきである。我々は、JT-60型ボロメータの性能を60Coガンマ線下で実証した。