The paper presents procedures which have been developed for a quantitative analysis of the divertor power deposition at Wendelstein 7-X. The development of these tools is motivated by the need to compare and verify scientific and engineering predictions with experimental measurements. The measurements have been performed by means of the thermographic diagnostic system, capable of exploring the divertor heat loads, with the aim to study the heat load symmetry, compare footprint patterns with theoretical expectations, but also investigate leading edges and divertor misalignment. In order to compare measurements and numerical calculations, an accurate mapping between the camera data, the divertor geometry and the 3D CAD models has been constructed. This mapping allows to find a correspondence between the data in different representations, simplifying data interpolation and visualization. This also provides a high resolution model of the target surface to compare numerical heat deposition calculations with experimental results from different cameras.
本論文は、Wendelstein 7-Xにおけるダイバータ電力堆積の定量的解析のために開発された手法を提示する。これらのツールの開発は、科学的および工学的予測を実験測定値と比較・検証する必要性によって動機づけられている。測定は、ダイバータ熱負荷を調査可能なサーモグラフィ診断システムを用いて実施され、熱負荷の対称性の研究、フットプリントパターンと理論的期待値との比較、さらにリーディングエッジおよびダイバータのミスアライメントの調査を目的としている。測定値と数値計算を比較するために、カメラデータ、ダイバータ形状、および3D CADモデル間の正確なマッピングが構築された。このマッピングにより、異なる表現におけるデータ間の対応関係を見出すことが可能となり、データの補間および可視化が簡素化される。また、これにより、数値的な熱堆積計算を異なるカメラからの実験結果と比較するための高解像度のターゲット表面モデルが提供される。