AbstractThe sustainment of radiative divertor plasma in JT-60U is performed by the feedback control of the gas puffing rate into the divertor region with an actuator of the divertor radiation power. The feedback control system switches the piezoelectric gas valve every 10 ms, so that the proper amount of gas flux is fed for divertor radiation power to follow the reference waveform. The divertor radiation of 6 MW, which is about 40% of the heating power, is sustained for about 3 s by the hydrogen gas puffing with feedback control. The present logic of the feedback system, however, is not sufficient to fully control the divertor radiation which is modified by the change in heatings and plasma parameters. In order to prevent the loss of control, multi actuators for the feedback control, for example, the involvement of the heating power, and the selection of observed bolometer channels may be required.
JT-60Uにおける放射ダイバータプラズマの維持は、ダイバータ領域へのガス入射量のフィードバック制御によって行われ、そのアクチュエータとしてダイバータ放射パワーが用いられる。フィードバック制御システムは圧電式ガスバルブを10msごとに切り替え、ダイバータ放射パワーが参照波形に追従するように適切なガス流量を供給する。水素ガス入射とフィードバック制御により、約6MWのダイバータ放射パワー(加熱パワーの約40%に相当)が約3秒間維持された。しかしながら、現在のフィードバックシステムのロジックでは、加熱やプラズマパラメータの変化によって変動するダイバータ放射を完全に制御するには不十分である。制御の喪失を防ぐためには、加熱パワーの関与などの複数のアクチュエータや、ボロメータチャンネルの選択などが必要となる可能性がある。