A double radiative feedback technique has been developed on the ASDEX Upgrade tokamak for optimization of power exhaust with a standard vertical target divertor. The main chamber radiation is measured in real time by a subset of three foil bolometer channels and controlled by argon injection in the outer midplane. The target heat flux is in addition controlled by nitrogen injection in the divertor private flux region using either a thermoelectric sensor or the scaled divertor radiation obtained by a bolometer channel in the outer divertor. No negative interference of the two radiation controllers has been observed so far. The combination of main chamber and divertor radiative cooling extends the operational space of a standard divertor configuration towards high values of P/R. Pheat/R = 14 MW m−1 has been achieved so far with nitrogen seeding alone as well as with combined N + Ar injection, with the time-averaged divertor peak heat flux below 5 MW m−2. Good plasma performance can be maintained under these conditions, namely H98(y,2) = 1 and βN = 3.
二重放射フィードバック手法が、標準的な垂直ターゲットダイバータを備えたASDEX Upgradeトカマクにおいて、排熱の最適化のために開発された。主チャンバー放射は、3つのフォイルボロメータチャンネルのサブセットによってリアルタイムに測定され、外側中平面でのアルゴン注入によって制御される。ターゲット熱流束はさらに、ダイバータ閉塞領域での窒素注入によって制御され、熱電センサーまたは外側ダイバータのボロメータチャンネルによって得られるスケーリングされたダイバータ放射のいずれかを使用する。これまでのところ、2つの放射制御器の間の負の干渉は観察されていない。主チャンバーとダイバータの放射冷却の組み合わせは、標準的なダイバータ配置の動作領域を高いP/R値に向けて拡張する。Pheat/R = 14 MW m−1がこれまでに窒素シーディング単独およびN + Ar複合注入の両方で達成されており、時間平均ダイバータピーク熱流束は5 MW m−2未満である。これらの条件下で良好なプラズマ性能を維持することができ、すなわちH98(y,2) = 1およびβN = 3である。