The global energy confinement characteristics of neutral beam heated JT-60 discharges are presented. There is a difference in the dependence of the energy confinement time on the plasma current between limiter and divertor discharges. For limiter discharges, the energy confinement increases with plasma current up to 3.2 MA, whereas for divertor discharges this improvement saturates when the safety factor drops below 3, independent of the location of the X-point. The JT-60 L-mode results indicate that the deterioration in energy confinement for q < 3, which is also found in H-mode regimes of other devices, may be a universal characteristic of divertor discharges. Regarding the scaling with plasma size, it is shown that the global/incremental confinement time increases with plasma minor radius. For sufficiently large plasmas, however, the global/incremental confinement time is no longer a function of minor radius.
中性粒子ビーム加熱されたJT-60放電の全球エネルギー閉じ込め特性を示す。リミター配位とダイバータ配位では、エネルギー閉じ込め時間のプラズマ電流依存性に差異が見られる。リミター配位では、エネルギー閉じ込め時間はプラズマ電流とともに3.2 MAまで増加するのに対し、ダイバータ配位では、安全係数が3を下回るとこの改善は飽和し、X点の位置に依存しない。JT-60のLモード結果は、q < 3におけるエネルギー閉じ込めの劣化が、他の装置のHモード領域でも見られることから、ダイバータ配位に共通の特性である可能性を示唆している。プラズマサイズに関するスケーリングについては、全球/増分閉じ込め時間はプラズマ小半径とともに増加することが示される。しかし、十分に大きなプラズマでは、全球/増分閉じ込め時間は小半径に依存しなくなる。