Energy transport in discharges with off-axis neutral beam injection (NBI) has been compared with transport in similar discharges with on-axis NBI. A two fluid power balance analysis assuming purely diffusive transport indicates substantial improvements in the plasma centre in both the ion and the electron channels during off-axis NBI. The ion thermal diffusivity, χi, and the angular momentum diffusivity, χϕ, in the plasma centre improve by over 2 orders of magnitude, and χi decreases below the Chang-Hinton neoclassical level. A detailed error analysis of the energy transport has been carried out. The electron thermal diffusivity in the plasma centre improves by an order of magnitude during off-axis NBI. The predicted peak ion temperature, assuming the same ion diffusivity profile for off-axis NBI as with on-axis NBI, is nearly a factor of 2 lower than the measured ion temperature profile with off-axis NBI. In addition, assuming unchanged diffusivities, significant inward energy flow is required to explain the observed ion temperature profiles during off-axis NBI.
オフアクシス中性粒子ビーム入射(NBI)を伴う放電におけるエネルギー輸送を、オンアクシスNBIを伴う同様の放電における輸送と比較した。純粋に拡散的輸送を仮定した二流体パワーバランス解析により、オフアクシスNBI中にイオンおよび電子の両チャネルにおいてプラズマ中心部で大幅な改善が示された。イオン熱拡散係数χiおよび角運動量拡散係数χϕは、プラズマ中心部で2桁以上改善し、χiはチャン・ヒントン新古典レベルを下回る。エネルギー輸送の詳細な誤差解析が実施された。電子熱拡散係数は、オフアクシスNBI中にプラズマ中心部で1桁改善する。オフアクシスNBIに対してオンアクシスNBIと同じイオン拡散係数プロファイルを仮定した場合の予測ピークイオン温度は、オフアクシスNBIで測定されたイオン温度プロファイルよりもほぼ2倍低い。さらに、拡散係数を不変と仮定すると、オフアクシスNBI中に観測されたイオン温度プロファイルを説明するには、有意な内向きのエネルギー流が必要である。